Calculate the U-value of your windows.
The U-value of a window, also called thermal transmittance, states per DIN EN 10077 how much heat is lost through the window to the outside. The lower the value, the less heat the window gives off.
Home / U-value calculator
The U-value of a window, also called thermal transmittance, states per DIN EN 10077 how much heat is lost through the window to the outside. The lower the value, the less heat the window gives off.
| Ug |
|---|
The unit is W/(m²K), watts per square meter and kelvin. The value describes the amount of energy per unit of time that flows through one square meter when the air temperature on the two sides differs by one kelvin.
Three values are distinguished for a window:
| Value | Meaning |
|---|---|
| Uw | thermal transmittance of the whole window |
| Uf | thermal transmittance of the frame |
| Ug | thermal transmittance of the glazing |
The Uw value results from frame and glass. Added to that is the heat loss at the glass edge, given as a psi value per linear meter. Because the shares of frame and glass depend on size, every format has its own Uw value.
The calculator works out the Uw value for your units. You choose the unit type, for example tilt-and-turn window, fixed glazing, lift-and-slide door, or entrance door, and enter width and height. The U-value in W/(m²K) is shown for each item.
The calculation assumes ENERsign primus with triple glazing at Ug = 0.52 W/(m²K) and a g-value of 53 %. Other glass is available on request.
| Element | Value | Basis |
|---|---|---|
| Window, tilt-and-turn | Uw = 0.60 W/(m²K) | EN 10077 |
| Window, fixed glazing | Uw = 0.59 W/(m²K) | EN 10077 |
Passive house windows must not exceed Uw = 0.80 W/(m²K). See the passive house page; the documents are listed under certificates.
Heat loss follows from area, U-value, and temperature difference:
Q = area (m²) × U-value (W/(m²K)) × temperature difference (K)
Example: a single-family house with 75 m² of window and door area, 22 °C inside, 0 °C outside, a difference of 22 K.
| Step | Comparison window | ENERsign primus |
|---|---|---|
| Average U-value | 0.91 W/(m²K) | 0.60 W/(m²K) |
| Calculation | 75 × 0.91 × 22 | 75 × 0.60 × 22 |
| Heat loss | about 1,500 W | 990 W |
The comparison window is a wood-aluminum window with triple glazing, Ug = 0.6 W/(m²K) and Uf = 1.2 W/(m²K).
The difference is about 0.51 kW. Over 220 heating days of 24 hours each, that comes to about 2,693 kWh per year, roughly 268 liters of heating oil or 297 m³ of natural gas.
The estimate is heavily simplified and does not distinguish by climate, orientation, or window sizes.
For a building's energy balance you need the Uw values of the actual formats. Contact us with your window schedule: Project inquiry.
Last updated: 2026-11-18
The earlier we join the design process, the slimmer the details become.