The passive house, explained.
A passive house (German: Passivhaus) is a building that covers most of its heating demand from passive sources: sunlight entering through the windows and the waste heat of people and appliances. Passive house is not a brand name. It is a building concept open to everyone.
What a passive house achieves
A passive house uses about 90 percent less heating energy than a typical existing building and more than 75 percent less than an average new build. Heating consumption is around 1.5 liters of heating-oil equivalent per square meter of living area per year.
Comfort is not what gets cut. Good insulation, airtight construction, and details free of thermal bridges avoid cold corners and drafts. That improves comfort in winter and summer and helps prevent building damage.
How the concept works
All passive buildings share a few principles:
- Continuous insulation: walls, roof, and floor slab form one highly insulated envelope without weak points.
- Windows: they keep heat inside and let solar energy in during winter, while summer heat gain is limited.
- Airtightness: the envelope is tight enough that conditioned air does not escape through gaps.
- Ventilation with heat recovery: a ventilation system supplies fresh air without drafts and recovers the heat of the exhaust air.
The core idea: fresh outdoor air has to reach every room anyway. If that air also carries the heat, the heating system becomes much simpler. This only works in a very well insulated building with a peak heating load below 10 W/m².
The passive house criteria
| Criterion | Requirement |
|---|---|
| Heating demand | below 15 kWh/(m²a) of living area |
| or heating load | below 10 W/m² |
| Primary energy demand | no more than 120 kWh/(m²a) |
| Airtightness | n50 no more than 0.6/h |
| Frequency of overheating in summer | below 10 % |
These figures apply to specific uses in a specific climate. The same standards do not apply everywhere; for other climate zones, separate values are derived from the passive house definition.
Why the window matters
Windows lose heat through the glass and through the frame. They are also the component through which a passive house gains solar energy. Large south-facing glass areas therefore make sense to capture as much winter sun as possible.
To be certified as a passive house window, a window must not exceed Uw = 0.80 W/(m²K) per EN 10077.
Window values at a glance
| Value | Meaning |
|---|---|
| Uw | thermal transmittance of the whole window |
| Uf | thermal transmittance of the frame |
| Ug | thermal transmittance of the glazing |
| Psi value | heat loss at the glass edge per linear meter |
| g-value | total solar energy transmittance: the higher, the more solar gain |
| TL value | light transmittance: the higher, the more daylight |
A lower U-value means better insulation. What counts is the interplay of frame profile, glass edge, and glazing. The page on the U-value calculator goes into more detail.
Certified components
Architects often cannot judge the energy performance of a component from manufacturer data alone. The Passive House Institute in Darmstadt, Germany, therefore tests products as an independent body and lists certified components in three groups: opaque envelope, building services, and transparent envelope.
Products certified as a “Passive House suitable component” are tested against uniform criteria, and their values can be compared. As a rule they are two to four times as efficient as common products.
Passive house and net zero
A net zero building produces as much energy as it consumes. The passive house principles are a basis for it: add an energy source, today most often a photovoltaic system, to a passive house, and the building can reach net zero.
Built passive houses with ENERsign
The Passive House Institute project database lists 74 built projects with ENERsign windows in nine countries: 53 in Germany, 11 in Canada, plus France, New Zealand, Japan, the USA, Greece, China and Denmark. They were built between 2007 and 2025, and 38 are certified (as of November 17, 2026). Each entry gives energy values, construction type and photographs: ENERsign projects in the Passive House project database. A selection of built houses is shown under Projects.
ENERsign primus in a passive house
The wood-aluminum ENERsign primus window is certified by the Passive House Institute. The wood interior provides insulation; the aluminum exterior resists rot and pests. Per EN 10077 the window reaches:
- tilt-and-turn: Uw = 0.60 W/(m²K)
- fixed glazing: Uw = 0.59 W/(m²K)
Certificates and certification reports are listed under certificates. If you are designing a passive house, talk to us early: Project inquiry.